1. Estimate the metal in the conductors
Use the number of equal conductors, the nominal cross-sectional area of each conductor and the cable length. Add unlike conductors separately.
Mass (kg) = number of conductors × area (mm²) × length (m) × density (g/cm³) ÷ 1,000.
Use about 8.96 g/cm³ for copper or 2.70 g/cm³ for aluminium. This estimates core metal only; shielding, armour and other metal parts are not included.
2. Worked example: 100 m of 3 × 2.5 mm² cable
For copper, 3 × 2.5 × 100 × 8.96 ÷ 1,000 = 6.72 kg. For aluminium conductors of the same nominal size, the result is 2.025 kg.
The cable metal calculator uses a factor of 1.00 for its GOST scenario and 0.89 for its TU scenario. The latter gives about 5.98 kg of copper in this example. It is an illustrative assumption, not a blanket rule for TU-marked cables. GOST 22483-2021 allows actual conductor area to differ from nominal subject to its resistance requirements.
4. Check a representative sample
Take a measured length from the lot. Weigh it intact, strip and weigh the conductors separately, and calculate the mass share. Sample several cable types or rolls if the lot is mixed. Keep shielding, armour and polymer separate when they have different resale values.